66 research outputs found

    Intramural duodenal hematoma: clinical course and imaging findings

    Get PDF
    Background: Intramural duodenal hematoma is a rare condition. Different imaging modalities are at hand for diagnosis. Purpose: To identify patients with intramural duodenal hematoma and report imaging findings and clinical courses. Material and Methods: Typical imaging patterns using ultrasound, computed tomography, and magnetic resonance imaging were carried out on 10 patients. Results: The mean patient age was 7.5 years. The average disease duration was 13 months. Clinical signs of improvement were observed within 16 days. Residues were still detectable at long-term follow-up. Conclusion: For patients with intramural duodenal wall hematoma, diagnosis should be considered early. Typical imaging findings should be known to ensure optimal treatment

    Cephalometric studies of the mandible, its masticatory muscles and vasculature of growing Göttingen Minipigs — A comparative anatomical study to refine experimental mandibular surgery

    Get PDF
    Over many decades, the Göttingen Minipig has been used as a large animal model in experimental surgical research of the mandible. Recently several authors have raised concerns over the use of the Göttingen Minipig in this research area, observing problems with post-operative wound healing and loosening implants. To reduce these complications during and after surgery and to improve animal welfare in mandibular surgery research, the present study elucidated how comparable the mandible of minipigs is to that of humans and whether these complications could be caused by specific anatomical characteristics of the minipigs’ mandible, its masticatory muscles and associated vasculature. Twenty-two mandibular cephalometric parameters were measured on CT scans of Göttingen Minipigs aged between 12 and 21 months. Ultimately, we compared this data with human data reported in the scientific literature. In addition, image segmentation was used to determine the masticatory muscle morphology and the configuration of the mandibular blood vessels. Compared to data of humans, significant differences in the mandibular anatomy of minipigs were found. Of the 22 parameters measured only four were found to be highly comparable, whilst the others were not. The 3D examinations of the minipigs vasculature showed a very prominent deep facial vein directly medial to the mandibular ramus and potentially interfering with the sectional plane of mandibular distraction osteogenesis. Damage to this vessel could result in inaccessible bleeding. The findings of this study suggest that Göttingen Minipigs are not ideal animal models for experimental mandibular surgery research. Nevertheless if these minipigs are used the authors recommend that radiographic techniques, such as computed tomography, be used in the specific planning procedures for the mandibular surgical experiments. In addition, it is advisable to choose suitable age groups and customize implants based on the mandibular dimensions reported in this study

    Exploring Patterns of Dynamic Size Changes of Lesions after Hepatic Microwave Ablation in an In Vivo Porcine Model

    Get PDF
    Microwave ablation (MWA) is a type of minimally invasive cancer therapy that uses heat to induce necrosis in solid tumours. Inter- and post-ablational size changes can influence the accuracy of control imaging, posing a risk of incomplete ablation. The present study aims to explore post-ablation 3D size dynamics in vivo using computed tomography (CT). Ten MWA datasets obtained in nine healthy pigs were used. Lesions were subdivided along the z-axis with an additional planar subdivision into eight subsections. The volume of the subsections was analysed over different time points, subsequently colour-coded and three-dimensionally visualized. A locally weighted polynomial regression model (LOESS) was applied to describe overall size changes, and Student's t-tests were used to assess statistical significance of size changes. The 3D analysis showed heterogeneous volume changes with multiple small changes at the lesion margins over all time points. The changes were pronounced at the upper and lower lesion edges and characterized by initially eccentric, opposite swelling, followed by shrinkage. In the middle parts of the lesion, we observed less dimensional variations over the different time points. LOESS revealed a hyperbolic pattern for the volumetric changes with an initially significant volume increase of 11.6% (111.6% of the original volume) over the first 32 minutes, followed by a continuous decrease to 96% of the original volume (p < 0.05)

    Improved Visualization of the Necrotic Zone after Microwave Ablation Using Computed Tomography Volume Perfusion in an In Vivo Porcine Model

    Get PDF
    After hepatic microwave ablation, the differentiation between fully necrotic and persistent vital tissue through contrast enhanced CT remains a clinical challenge. Therefore, there is a need to evaluate new imaging modalities, such as CT perfusion (CTP) to improve the visualization of coagulation necrosis. MWA and CTP were prospectively performed in five healthy pigs. After the procedure, the pigs were euthanized, and the livers explanted. Orthogonal histological slices of the ablations were stained with a vital stain, digitalized and the necrotic core was segmented. CTP maps were calculated using a dual-input deconvolution algorithm. The segmented necrotic zones were overlaid on the DICOM images to calculate the accuracy of depiction by CECT/CTP compared to the histological reference standard. A receiver operating characteristic analysis was performed to determine the agreement/true positive rate and disagreement/false discovery rate between CECT/CTP and histology. Standard CECT showed a true positive rate of 81% and a false discovery rate of 52% for display of the coagulation necrosis. Using CTP, delineation of the coagulation necrosis could be improved significantly through the display of hepatic blood volume and hepatic arterial blood flow (p < 0.001). The ratios of true positive rate/false discovery rate were 89%/25% and 90%/50% respectively. Other parameter maps showed an inferior performance compared to CECT

    Comparing different deep learning architectures for classification of chest radiographs

    Get PDF
    Chest radiographs are among the most frequently acquired images in radiology and are often the subject of computer vision research. However, most of the models used to classify chest radiographs are derived from openly available deep neural networks, trained on large image datasets. These datasets differ from chest radiographs in that they are mostly color images and have substantially more labels. Therefore, very deep convolutional neural networks (CNN) designed for ImageNet and often representing more complex relationships, might not be required for the comparably simpler task of classifying medical image data. Sixteen different architectures of CNN were compared regarding the classification performance on two openly available datasets, the CheXpert and COVID-19 Image Data Collection. Areas under the receiver operating characteristics curves (AUROC) between 0.83 and 0.89 could be achieved on the CheXpert dataset. On the COVID-19 Image Data Collection, all models showed an excellent ability to detect COVID-19 and non-COVID pneumonia with AUROC values between 0.983 and 0.998. It could be observed, that more shallow networks may achieve results comparable to their deeper and more complex counterparts with shorter training times, enabling classification performances on medical image data close to the state-of-the-art methods even when using limited hardware

    Computed Tomography Imaging in Simulated Ongoing Cardiopulmonary Resuscitation: No Need to Switch Off the Chest Compression Device during Image Acquisition

    Get PDF
    Computed tomography (CT) represents the current standard for imaging of patients with acute life-threatening diseases. As some patients present with circulatory arrest, they require cardiopulmonary resuscitation. Automated chest compression devices are used to continue resuscitation during CT examinations, but tend to cause motion artifacts degrading diagnostic evaluation of the chest. The aim was to investigate and evaluate a CT protocol for motion-free imaging of thoracic structures during ongoing mechanical resuscitation. The standard CT trauma protocol and a CT protocol with ECG triggering using a simulated ECG were applied in an experimental setup to examine a compressible thorax phantom during resuscitation with two different compression devices. Twenty-eight phantom examinations were performed, 14 with AutoPulse and 14 with corpuls cpr. With each device, seven CT examinations were carried out with ECG triggering and seven without. Image quality improved significantly applying the ECG-triggered protocol (p < 0.001), which allowed almost artifact-free chest evaluation. With the investigated protocol, radiation exposure was 5.09% higher (15.51 mSv vs. 14.76 mSv), and average reconstruction time of CT scans increased from 45 to 76 s. Image acquisition using the proposed CT protocol prevents thoracic motion artifacts and facilitates diagnosis of acute life-threatening conditions during continuous automated chest compression

    Evaluation of potential tissue heating during percutaneous drill-assisted bone sampling in an in vivo porcine study

    Get PDF
    Background: Minimally invasive, battery-powered drilling systems have become the preferred tool for obtaining representative samples from bone lesions. However, the heat generated during battery-powered bone drilling for bone biopsies has not yet been sufficiently investigated. Thermal necrosis can occur if the bone temperature exceeds a critical threshold for a certain period of time. Purpose: To investigate heat production as a function of femur temperature during and after battery-powered percutaneous bone drilling in a porcine in vivo model. Methods: We performed 16 femur drillings in 13 domestic pigs with an average age of 22 weeks and an average body temperature of 39.7 degrees C, using a battery-powered drilling system and an intraosseous temperature monitoring device. The standardized duration of the drilling procedure was 20 s. The bone core specimens obtained were embedded in 4% formalin, stained with haematoxylin and eosin (H&E) and sent for pathological analysis of tissue quality and signs of thermal damage. Results: No significant changes in the pigs' local temperature were observed after bone drilling with a battery-powered drill device. Across all measurements, the median change in temperature between the initial measurement and the temperature measured after drilling (at 20 s) was 0.1 degrees C. Histological examination of the bone core specimens revealed no signs of mechanical or thermal damage. Conclusion: Overall, this preliminary study shows that battery-powered, drill-assisted harvesting of bone core specimens does not appear to cause mechanical or thermal damage

    Deep learning for accurately recognizing common causes of shoulder pain on radiographs

    Get PDF
    Objective: Training a convolutional neural network (CNN) to detect the most common causes of shoulder pain on plain radiographs and to assess its potential value in serving as an assistive device to physicians. Materials and methods: We used a CNN of the ResNet-50 architecture which was trained on 2700 shoulder radiographs from clinical practice of multiple institutions. All radiographs were reviewed and labeled for six findings: proximal humeral fractures, joint dislocation, periarticular calcification, osteoarthritis, osteosynthesis, and joint endoprosthesis. The trained model was then evaluated on a separate test dataset, which was previously annotated by three independent expert radiologists. Both the training and the test datasets included radiographs of highly variable image quality to reflect the clinical situation and to foster robustness of the CNN. Performance of the model was evaluated using receiver operating characteristic (ROC) curves, the thereof derived AUC as well as sensitivity and specificity. Results: The developed CNN demonstrated a high accuracy with an area under the curve (AUC) of 0.871 for detecting fractures, 0.896 for joint dislocation, 0.945 for osteoarthritis, and 0.800 for periarticular calcifications. It also detected osteosynthesis and endoprosthesis with near perfect accuracy (AUC 0.998 and 1.0, respectively). Sensitivity and specificity were 0.75 and 0.86 for fractures, 0.95 and 0.65 for joint dislocation, 0.90 and 0.86 for osteoarthrosis, and 0.60 and 0.89 for calcification. Conclusion: CNNs have the potential to serve as an assistive device by providing clinicians a means to prioritize worklists or providing additional safety in situations of increased workload

    A morphometric study of the mandibular canal

    Get PDF
    This study reports morphometric and age-related data of the mandibular canal and the alveolar ridge of the Göttingen Minipig to avoid complications during in vivo testing of endosseus dental implants and to compare these data with the human anatomy. Using 3D computed tomography, six parameters of the mandibular canal as well as the alveolar bone height and the alveolar ridge width were measured in Göttingen Minipigs aged 12, 17 and 21 months. Our null hypothesis assumes that the age and the body mass have an influence on the parameters measured. The study found that the volume, length and depth of the mandibular canal all increase with age. The width of the canal does not change significantly with age. The body mass does not have an influence on any of the measured parameters. The increase in canal volume appears to be due to loss of deep spongy bone in the posterior premolar and molar regions. This reduces the available space for dental implantations, negatively affecting implant stability and potentially the integrity of the inferior alveolar neurovascular bundle. Dynamic anatomical changes occur until 21 months. On ethical grounds, using minipigs younger than 21 months in experimental implant dentistry is inadvisable. Paradoxically the measurements of the 12 months old pigs indicate a closer alignment of their mandibular anatomy to that of humans suggesting that they may be better models for implant studies. Given the variability in mandibular canal dimensions in similar age cohorts, the use of imaging techniques is essential for the selection of individual minipigs for dental prosthetic interventions and thus higher success rates
    • …
    corecore